If the sewage mixer stops suddenly during operation, it can be treated according to the following steps:
First, stop the machine immediately for inspection
Power off: The first thing to do is to immediately turn off the power to the blender to ensure that the equipment is in a safe state to prevent further damage or safety incidents.
Second, troubleshoot the cause of the failure
Check power and electrical systems:
Check whether the power supply is normal, and check whether the cables and connections are damaged or loose.
Check if the motor is overheating or damaged, motor failure is one of the common reasons for the sudden stop of the mixer.
Check the electrical system for short circuit, open circuit or abnormal current.
Check mechanical parts:
Check the blade of the mixer for imbalance, damage or blockage, which will affect the normal operation of the mixer.
Check whether bearings need to be replaced or lubricated, bearing damage or insufficient lubrication may also cause the mixer to stop.
Check whether the transmission system (such as belt, chain, etc.) is intact, and the transmission failure will also cause the mixer to not work normally.
Check materials and loads:
Check whether the mixer has added materials that do not meet the specifications, such as large particles, hard objects, etc., which may cause the mixing shaft to stick or the load is too large.
Check the load of the mixer to ensure that it is operating within the rated load range.
Check safety devices:
Check whether the safety protection device of the mixer is triggered, such as whether the emergency stop button is pressed by mistake.
Check whether the two rubber side walls of the mixer are closed tightly, if they are not closed tightly, the system may stop working automatically.
Third, take countermeasures
Clean up and repair:
If the shutdown is caused by material blockage or blade imbalance, the blockage should be cleaned and the blade position adjusted.
If mechanical parts are found to be damaged, they should be repaired or replaced in time.
Adjustment operation:
If the shutdown is caused by improper operation, such as the wrong starting sequence or excessive load, adjust the operation method and restart the device.
Contact Professionals:
If you can not determine the cause of the fault or can not deal with the fault, should promptly contact professional maintenance personnel for inspection and maintenance.
Fourth, preventive measures
Regular inspection and maintenance: Regular inspection and maintenance of the sewage mixer, including electrical systems, mechanical components and safety devices, to ensure that the equipment is in good condition.
Correct operation: Operate according to the operation manual and specifications to avoid improper operations such as overload and long-term continuous operation.
Operator training: Provide professional training for operators to improve their familiarity with the equipment and operation skills, and reduce faults caused by improper operations.
Through the above steps, you can effectively deal with the problem of sudden stop of the sewage mixer, and ensure that the equipment can resume normal operation as soon as possible.
Nanjing LanJiang Water Treatment Equipment Co.,Ltd manufactures equipment for wastewater treatment. We were established in 2001. Since then, we designed and produced submersible mixers, top entry mixers, aerators and other wastewater treatment equipment.